Warning: This is not a tutorial. I do not recommend messing with mains voltage unless you are qualified, which I am not.
A few months ago, my KRK Rokit 7 speakers started getting caught in a boot loop where the screen would just flash instead of powering on. I was able to get around it for a while by flipping the power switch on and off a few times until they eventually powered up, but recently one of the speakers just completely died, and wouldn't show any signs of life at all.
Opening it up, I noticed that the capacitor labeled C7 on the power supply board was slightly bulging. After looking online, this is apparently common:

The faulty capacitor is located here on the power supply board, circled in red:

Removing the board is pretty easy, just need to remove the mains power connector, unscrew it from the standoffs holding it in place, and then slide it sideways off the connectors connecting it to the other board.
Be wary of and be sure to discharge the main big capacitor in the center of the board, as it holds a lot of energy (9.6J) and can deliver a dangerous shock even after the speaker is unplugged for a while.
Sourcing the replacement capacitor was easy, as 1000uf / 10V / low ESR capacitors are quite common, I got a few from a local store for under a dollar.
Swapping over the capacitors was straightforward, just make sure that you don't damage the transformer wires nearby that are held in place by the same goo that's surrounding the capacitor, and that you make sure the white stripe on the capacitor aligns with the white polarity mark under the board where the capacitor was:


And yep, turns out that single capacitor was the sole culprit, and after reassembling the speaker, it powered on and works fine again without any issues: